Medical Equipment and Health Products
Trismed 12 Channel ECG Cardipia 800H, Korea
Updated
Specifications
Performance
| Performance | AAMI standard requirements |
|---|
Other
| Recording Leads | 12 standard leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 |
|---|---|
| Recording Channel | 12-ch x 1, 6-ch x 2, 6-ch x 2+1R, 3-ch x 4, 3-ch x 4+1R, 3-ch x 4+3R (R: Rhythm) |
| Recording Lead Group | Standard / Cabrera / Nehb / User-selectable group |
| Recording Mode | Auto, Manual, Rhythm, Periodic, Auto Start, Elapsed, Calibration(1mV), Copy, TPH test |
| Full Disclosure Report | Min. 10 sec ~ Max. 10 min. by user set / Manual mode |
| Recording Length | Min. 3 sec ~ Max. 85 sec. by user select ( Auto mode only ) |
| Recording system | Thermal printer head ( 8 dots/mm) / 203 (vertical) x 508 (horizontal) dpi |
| x 30 m | 210 mm (L) x 60 mm (W) x 400 sheets |
| Sensitivity (mm/mV) | 2.5, 5, 10, 20, 40, Auto |
| Interpretation (option) | Adult / Pediatric, Mean cardiac cycle with segment and measurement |
| Stress ECG I/F (option) | Wire (RS232/USB) / Bluetooth. Treadmill/Ergometer and PC stress ECG S/W are required |
| 5, 10, 12.5, 25, 50, 100 | 25, 50 |
| Key Operation | Alphanumeric PC key by membrane and LCD touch screen |
| Calibration Signal | Sensitivity and frequency response test by using an internal 1 mV |
| Language | English / Spanish / French / Russian / Turkish / Mongolian / others by user request |
| ECG Data Acquisition | Simultaneous 12-lead ECG |
| Input Impedance | Greater than 100 MΩ per 10 Hz |
| A/D Resolution | 16 bits (0.17 µV/bit) Option : 24bits (1.25 µV/bit) |
| A/D Sampling Rate | 8,000 samples/8-lead/sec. |
| CMRR | Greater than 100 dB |
| Frequency Response | 0.05 ~ 200 Hz ( -3dB unfiltered ) |
| Time Constant | Greater than 3.2 sec. |
| Pace Maker Detection | Option |
| Arrhythmia Detection | Auto extend recording time to 20 ~ 60 sec by Ventricular Tachycardia and Bradycardia |
| Data Management | Save / Delete / Copy / Review / Transfer / Measure |
| Data Transfer I/F to HIS | USB memory stick / USB port / Ethernet LAN / Bluetoot (option) / WiFi (option) |
| TRISMED PCNet S/W | Via Wire USB / Bluetooth / USB memory / LAN/WiFi |
| HIS Data I/F | HL7 / XML / SCP / PDF /JPG/ PNG / DICOM(PACS) |
| External Device I/F | Barcode Reader / Magnetic card reader / printer :HP PSC1310 series, HP LeserJet Pro M201 M202 series |
| Patient Leakage Current | Less than 10μA |
| Electrical Safety | Class I (Degree of protection against electrical shock) |
| CARDIPIA800H | 333 (L) x 310 (W) x 105 (H) |
| Temperature | Operating : +10 ~ +40 ℃ / Transport or Storage : -20 ~ +60 ℃ |
| Relative Humidity | Operating : 30~75 % (non-condensing) / Transport or Storage: 10~90 % (non-condensing) |
| Diverse formats of HIS data | HL7, XML, SCP, PDF DICOM(PACS)-PACS |
| I / F data transfer | USB (RS232), LAN for the Ethernet, Bluetooth Variant |
| External I / F device | Barcode / External Printer and Learner of cards |
Display
| Display | Color TFT 7” LCD (Viewing area : 154.08mm x 85.92mm), Dots : 800 x 480 |
|---|---|
| Display Channel (Ch) | 12 (6-ch x 2), 6 (3-ch x 2), 3 (3-ch x 1), 4 (2-ch x 2), 2 (2-ch x 1), 1 (1-ch x 1) |
| QRS Beat Display & Sound | 30 ~ 240 bpm on real time. |
| Alarm Display and Sound | Lead-off detection for individual 10 lead, Battery level, Paper empty, HR. |
Memory
| Data Save Memory (10 sec) | Internal memory: Standard 4,000 records / Optional SD card (12,000 records per 1GB) / Optional external USB memory stick (12,000 records per 1GB) |
|---|---|
| The memory of the data | internal SD card / external USB memory |
Battery
| Battery | Built-in rechargeable battery. NiMH19.2V (2200mA) / 420 reports (150 min) per 12-ch x 1 (5 sec) auto record by fully charged battery |
|---|
Advertisement
Prices seen in Bangladesh
| Seller | Price | Seen on |
|---|---|---|
| BMA Bazar Shop | ৳160,000 | October 29, 2026 |
Prices as published by each seller on the date shown. They change often; confirm with the seller before you buy.
User reviews
No reviews yet. Do you own a Trismed 12 Channel ECG Cardipia 800H, Korea? Be the first to rate it.
Discussion
Messages are written by visitors, not by Ratings.bd. Do not share phone numbers or medical advice here.
Writing here is not available right now. Please try later.
Advertisement