Skip to content
IPS and Inverters

GoodWe 50kW GW50K-ET-10 Three Phase Hybrid Inverter

Brand: GOODWE

Updated

Specifications

General

Parameter Value
Max. Input Current per MPPT (A) 42/32/42/32
Max. Short Circuit Current per MPPT (A) 55/42/55/42
Number of MPPT Trackers 4
Number of Strings per MPPT 2
Nominal AC Grid Frequency (Hz) 50/60
AC Grid Frequency Range (Hz) 45-55/55-65
Max. AC Current From Utility Grid (A) 75.8 @380V / 72.5 @400V
Nominal AC Current From Utility Grid (A) 75.8 @380V / 72.5 @400V
Max. Output Fault Current (A) 178@2μs
Inrush Current (A) 178@2μs
Nominal Output Current (A) 75.8 @380V / 72.5 @400V
Max. Output Current (A) 83.3 @380V / 79.7 @400V
Inrush Current (Peak and Duration) (A) 178@2μs
Nominal Output Frequency (Hz) 50/60
Max. Efficiency 98.1%
European Efficiency 97.5%
MPPT Efficiency 99%
Residual Current Monitoring Integrated
PV Reverse Polarity Protection Integrated
Anti-islanding Protection Integrated
AC Overcurrent Protection Integrated
AC Short Circuit Protection Integrated
DC Switch Integrated
DC Surge Protection Type II (Type I+II Optional)
AC Surge Protection Type II
AFCI Optional
Remote Shutdown Integrated
Operating Temperature Range (℃) -35~+60
Operating Environment Outdoor
Relative Humidity 0~95%
Max. Operating Altitude (m) 4000
Cooling Method Smart Fan Cooling
User Interface LED, WLAN+APP
Communication with BMS CAN
Communication with Meter RS485
Communication with Portal RS485, WiFi+LAN+Bluetooth, 4G+Bluetooth(Optional)
Noise Emission (dB) 56
Topology Non-isolated
Ingress Protection Rating IP66
DC Connector MC4 (4~6mm2)
AC Connector OT
Environmental Category 4K4H
Pollution Degree PD 3 (External), PD 2 (Internal)
Protective Class I
Storage Temperature (℃) -40~+85
Mounting Method Wall Mounted
Active Anti-islanding Method AFDPF + AQDPF *7
Type of Electrical Supply System Three phase Grid
Country of Manufacture China
Grid Standards NRS097-2-1, VDE-AR-N 4105, PPDS 2021Type A2, 50549-1, NBT32004
Safety Regulation IEC62109-1&2
EMC EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
PV Input Terminals 4 MPPT trackers with 2 strings per MPPT (8 PV inputs total).
BMS Communication BMS port (CAN communication).
AC Output (On-Grid) ON-GRID port (3L/N/PE).
Back-Up Output BACK-UP port (3L/N/PE) via STS.
Generator Input GEN port (3L/N/PE) via STS.
Smart Meter/CT Meter port (RS485).
Communication RS485, CAN, WiFi/LAN, 4G, Bluetooth.
Parallel Communication PAR1 and PAR2 ports (RJ45).
Load Control Dry contact port (LOAD CON, max 24Vdc, 1A).
Remote Shutdown / Rapid Shutdown DI port.
Diesel Generator Control DIESEL GEN port.
EMS Connection EMS port (RS485).
Real-Time Monitoring View PV generation, battery status, load consumption, and grid export/import data.
Energy Flow Chart Visual representation of energy flow between PV, battery, load, and grid.
Remote Configuration Set working modes (Self-use, Back-up, TOU, Off-grid, Smart Charging, Peak Shaving).
Firmware Upgrade Regular, one-click, and automatic firmware upgrade via the app.
Fault Diagnostics View fault codes, alarm history, and troubleshooting recommendations.
Parallel System Settings Configure master/slave inverters and parallel networking.

Dimensions

Weight (kg) 65
Dimension (W×H×D mm) 520×660×260

Power

Battery Type Li-Ion
Nominal Battery Voltage (V) 500
Battery Voltage Range (V) 200 ~ 800
Start-up Voltage (V) 200
Number of Battery Input 1
Max. Continuous Charging Current (A) 100
Max. Continuous Discharging Current (A) 100
Max. Charging Power (W) 55000
Max. Discharging Power (W) 55000
Max. Input Power (W) *1 75000
Max. Input Voltage (V) *4 1000
MPPT Operating Voltage Range (V) *6 165 ~ 850
MPPT Voltage Range at Nominal Power (V) 400~850
Nominal Input Voltage (V) 620
Nominal Output Power (W) 50000
Max. Output Power (W) 50000
Nominal Output Voltage (V) 380/400, 3L/N/PE
Output Voltage Range (V) *2 176~276
Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Back-up Nominal Apparent Power (VA) 50000
Max. Output Apparent Power (VA) 55,000 (60,000 at 60sec, 75,000 at 10sec)
Max. Battery to AC Efficiency 97.7%
Battery Reverse Polarity Protection Integrated
AC Overvoltage Protection Integrated
Overvoltage Category DC II / AC III
Decisive Voltage Class (DVC) Battery: C, PV: C, AC: C, Com: A
Battery Input BAT+ and BAT- for high-voltage battery connection.
Battery Management Configure battery parameters, SOC limits, charge/discharge schedules, and battery wake-up.
Export Power Limit Set grid export limits to comply with local regulations.
Advertisement

Prices seen in Bangladesh

SellerPriceSeen on
SOLAR BD ৳500,000 October 30, 2026

Prices as published by each seller on the date shown. They change often; confirm with the seller before you buy.

User reviews

No reviews yet. Do you own a GoodWe 50kW GW50K-ET-10 Three Phase Hybrid Inverter? Be the first to rate it.

Share your experience

How many stars would you give?

Advertisement