Skip to content
Medical Equipment and Health Products

Trismed 12 Channel ECG Cardipia 800H, Korea

Updated

Specifications

Performance

Performance AAMI standard requirements

Other

Recording Leads 12 standard leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Recording Channel 12-ch x 1, 6-ch x 2, 6-ch x 2+1R, 3-ch x 4, 3-ch x 4+1R, 3-ch x 4+3R (R: Rhythm)
Recording Lead Group Standard / Cabrera / Nehb / User-selectable group
Recording Mode Auto, Manual, Rhythm, Periodic, Auto Start, Elapsed, Calibration(1mV), Copy, TPH test
Full Disclosure Report Min. 10 sec ~ Max. 10 min. by user set / Manual mode
Recording Length Min. 3 sec ~ Max. 85 sec. by user select ( Auto mode only )
Recording system Thermal printer head ( 8 dots/mm) / 203 (vertical) x 508 (horizontal) dpi
x 30 m 210 mm (L) x 60 mm (W) x 400 sheets
Sensitivity (mm/mV) 2.5, 5, 10, 20, 40, Auto
Interpretation (option) Adult / Pediatric, Mean cardiac cycle with segment and measurement
Stress ECG I/F (option) Wire (RS232/USB) / Bluetooth. Treadmill/Ergometer and PC stress ECG S/W are required
5, 10, 12.5, 25, 50, 100 25, 50
Key Operation Alphanumeric PC key by membrane and LCD touch screen
Calibration Signal Sensitivity and frequency response test by using an internal 1 mV
Language English / Spanish / French / Russian / Turkish / Mongolian / others by user request
ECG Data Acquisition Simultaneous 12-lead ECG
Input Impedance Greater than 100 MΩ per 10 Hz
A/D Resolution 16 bits (0.17 µV/bit) Option : 24bits (1.25 µV/bit)
A/D Sampling Rate 8,000 samples/8-lead/sec.
CMRR Greater than 100 dB
Frequency Response 0.05 ~ 200 Hz ( -3dB unfiltered )
Time Constant Greater than 3.2 sec.
Pace Maker Detection Option
Arrhythmia Detection Auto extend recording time to 20 ~ 60 sec by Ventricular Tachycardia and Bradycardia
Data Management Save / Delete / Copy / Review / Transfer / Measure
Data Transfer I/F to HIS USB memory stick / USB port / Ethernet LAN / Bluetoot (option) / WiFi (option)
TRISMED PCNet S/W Via Wire USB / Bluetooth / USB memory / LAN/WiFi
HIS Data I/F HL7 / XML / SCP / PDF /JPG/ PNG / DICOM(PACS)
External Device I/F Barcode Reader / Magnetic card reader / printer :HP PSC1310 series, HP LeserJet Pro M201 M202 series
Patient Leakage Current Less than 10μA
Electrical Safety Class I (Degree of protection against electrical shock)
CARDIPIA800H 333 (L) x 310 (W) x 105 (H)
Temperature Operating : +10 ~ +40 ℃ / Transport or Storage : -20 ~ +60 ℃
Relative Humidity Operating : 30~75 % (non-condensing) / Transport or Storage: 10~90 % (non-condensing)
Diverse formats of HIS data HL7, XML, SCP, PDF DICOM(PACS)-PACS
I / F data transfer USB (RS232), LAN for the Ethernet, Bluetooth Variant
External I / F device Barcode / External Printer and Learner of cards

Display

Display Color TFT 7” LCD (Viewing area : 154.08mm x 85.92mm), Dots : 800 x 480
Display Channel (Ch) 12 (6-ch x 2), 6 (3-ch x 2), 3 (3-ch x 1), 4 (2-ch x 2), 2 (2-ch x 1), 1 (1-ch x 1)
QRS Beat Display & Sound 30 ~ 240 bpm on real time.
Alarm Display and Sound Lead-off detection for individual 10 lead, Battery level, Paper empty, HR.

Memory

Data Save Memory (10 sec) Internal memory: Standard 4,000 records / Optional SD card (12,000 records per 1GB) / Optional external USB memory stick (12,000 records per 1GB)
The memory of the data internal SD card / external USB memory

Battery

Battery Built-in rechargeable battery. NiMH19.2V (2200mA) / 420 reports (150 min) per 12-ch x 1 (5 sec) auto record by fully charged battery
Advertisement

Prices seen in Bangladesh

SellerPriceSeen on
BMA Bazar Shop ৳160,000 October 29, 2026

Prices as published by each seller on the date shown. They change often; confirm with the seller before you buy.

User reviews

No reviews yet. Do you own a Trismed 12 Channel ECG Cardipia 800H, Korea? Be the first to rate it.

Share your experience

How many stars would you give?

Discussion

Messages are written by visitors, not by Ratings.bd. Do not share phone numbers or medical advice here.

    Advertisement